The Home Depot X12 864 Text Message

Home Depot US (RDC/DTS)

3 schema elements found

This Draft Standard schema for Trial Use contains the format and data contents of the schema for use within the context of an Electronic Data Interchange (EDI) environment.

ISA

ISA

Interchange Control Header

MMax: 1

To start and identify an interchange of zero or more functional groups and interchange-related control segments

ISA01
Authorization Information Qualifier
MIDMIN 2 MAX 2ID: I01

Code identifying the type of information in the Authorization Information

ISA02
Authorization Information
MANMIN 10 MAX 10ID: I02

Information used for additional identification or authorization of the interchange sender or the data in the interchange; the type of information is set by the Authorization Information Qualifier (I01)

ISA03
Security Information Qualifier
MIDMIN 2 MAX 2ID: I03

Code identifying the type of information in the Security Information

ISA04
Security Information
MANMIN 10 MAX 10ID: I04

This is used for identifying the security information about the interchange sender or the data in the interchange; the type of information is set by the Security Information Qualifier (I03)

ISA05
Interchange ID Qualifier
MIDMIN 2 MAX 2ID: I05

Code indicating the system/method of code structure used to designate the sender or receiver ID element being qualified

ISA06
Interchange Sender ID
MANMIN 15 MAX 15ID: I06

Identification code published by the sender for other parties to use as the receiver ID to route data to them; the sender always codes this value in the sender ID element

ISA07
Interchange ID Qualifier
MIDMIN 2 MAX 2ID: I05

Code indicating the system/method of code structure used to designate the sender or receiver ID element being qualified

ISA08
Interchange Receiver ID
MANMIN 15 MAX 15ID: I07

Identification code published by the receiver of the data; When sending, it is used by the sender as their sending ID, thus other parties sending to them will use this as a receiving ID to route data to them

ISA09
Interchange Date
MDTMIN 6 MAX 6ID: I08

Date of the interchange

ISA10
Interchange Time
MTMMIN 4 MAX 4ID: I09

Time of the interchange

ISA11
Repetition Separator
MMIN 1 MAX 1ID: I65

Type is not applicable; the repetition separator is a delimiter and not a data element; this field provides the delimiter used to separate repeated occurrences of a simple data element or a composite data structure; this value must be different than the data element separator, component element separator, and the segment terminator

ISA12
Interchange Control Version Number
MIDMIN 5 MAX 5ID: I11

Code specifying the version number of the interchange control segments

ISA13
Interchange Control Number
MN0MIN 9 MAX 9ID: I12

A control number assigned by the interchange sender

ISA14
Acknowledgment Requested
MIDMIN 1 MAX 1ID: I13

Code indicating sender's request for an interchange acknowledgment

ISA15
Interchange Usage Indicator
MIDMIN 1 MAX 1ID: I14

Code indicating whether data enclosed by this interchange envelope is test, production or information

ISA16
Component Element Separator
MMIN 1 MAX 1ID: I15

Type is not applicable; the component element separator is a delimiter and not a data element; this field provides the delimiter used to separate component data elements within a composite data structure; this value must be different than the data element separator and the segment terminator

GS

GS

Functional Group Header

MMax: 1

To indicate the beginning of a functional group and to provide control information

GS01
Functional Identifier Code
MIDMIN 2 MAX 2ID: 479

Code identifying a group of application related transaction sets

GS02
Application Sender's Code
MANMIN 2 MAX 15ID: 142

Code identifying party sending transmission; codes agreed to by trading partners

GS03
Application Receiver's Code
MANMIN 2 MAX 15ID: 124

Code identifying party receiving transmission; codes agreed to by trading partners

GS04
Date
MDTMIN 8 MAX 8ID: 373

Date expressed as CCYYMMDD where CC represents the first two digits of the calendar year

GS05
Time
MTMMIN 4 MAX 8ID: 337

Time expressed in 24-hour clock time as follows: HHMM, or HHMMSS, or HHMMSSD, or HHMMSSDD, where H = hours (00-23), M = minutes (00-59), S = integer seconds (00-59) and DD = decimal seconds; decimal seconds are expressed as follows: D = tenths (0-9) and DD = hundredths (00-99)

GS06
Group Control Number
MN0MIN 1 MAX 9ID: 28

Assigned number originated and maintained by the sender

GS07
Responsible Agency Code
MIDMIN 1 MAX 2ID: 455

Code identifying the issuer of the standard; this code is used in conjunction with Data Element 480

GS08
Version / Release / Industry Identifier Code
MANMIN 1 MAX 12ID: 480

Code indicating the version, release, subrelease, and industry identifier of the EDI standard being used, including the GS and GE segments; if code in DE455 in GS segment is X, then in DE 480 positions 1-3 are the version number; positions 4-6 are the release and subrelease, level of the version; and positions 7-12 are the industry or trade association identifiers (optionally assigned by user); if code in DE455 in GS segment is T, then other formats are allowed

transactionSets

Loop: transactionSets

ST

Transaction Set Header

MMax: 1Area: 1Seq: 0100

To indicate the start of a transaction set and to assign a control number

ST01
Transaction Set Identifier Code
MIDMIN 3 MAX 3ID: 143

Code uniquely identifying a Transaction Set

864Text Message
ST02
Transaction Set Control Number
MANMIN 4 MAX 9ID: 329

Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set

BMG

Beginning Segment For Text Message

MMax: 1Area: 1Seq: 0200

To indicate the beginning of a Text Message Transaction Set

BMG01
Transaction Set Purpose Code
MIDMIN 2 MAX 2ID: 353

Code identifying purpose of transaction set

00Original
01Cancellation
02Add
03Delete
04Change
05Replace
06Confirmation
07Duplicate
08Status
10Not Found
11Response
12Not Processed
13Request
14Advance Notification
15Re-Submission
16Proposed
17Cancel, to be Reissued
18Reissue
19Seller initiated change
20Final Transmission
21Transaction on Hold
22Information Copy
24Draft
25Incremental
26Replace - Specified Buyers Parts Only
27Verify
28Query
30Renewal
31Allowance/Addition
32Recovery/Deduction
33Request for Payment
34Payment Declined
35Request Authority
36Authority to Deduct (Reply)
37Authority Declined (Reply)
38No Financial Value
39Response to Proposed Trip Plan
40Commitment Advice
41Corrected and Verified
42Temporary Record
43Request Permission to Service
44Rejection
45Follow-up
46Cancellation with Refund
47Transfer
48Suspended
49Original - No Response Necessary
50Register
51Historical Inquiry
52Response to Historical Inquiry
53Completion
54Approval
55Excavation
56Expiration Notification
57Initial
5CChargeable Resubmission
77Simulation Exercise
CNCompletion Notification
COCorrected
EXFinal Loading Configuration
GRGranted
PRProposed Loading Configuration
RHRelease Hold
RVRevised Loading Configuration
SUStatus Update
ZZMutually Defined
BMG02
Description
OANMIN 1 MAX 80ID: 352

A free-form description to clarify the related data elements and their content

Loop: MIT_loop

Repeat: >1
MIT

Message Identification

MMax: 1Area: 2Seq: 0100

To identify the beginning of a specific message and to allow the identification of a subject for the message

MIT01
Reference Identification
MANMIN 1 MAX 50ID: 127

Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier

MIT02
Description
OANMIN 1 MAX 80ID: 352

A free-form description to clarify the related data elements and their content

MIT03
Page Width
ON0MIN 1 MAX 3ID: 931

Definition of the maximum number of characters per line that can be expected in the message text

MIT04
Page Length Lines
ON0MIN 1 MAX 3ID: 932

Definition of the maximum number of lines per page that can be expected in the message text

MSG

Message Text

MMax: >1Area: 2Seq: 0800

To provide a free-form format that allows the transmission of text information

MSG01
Free-form Message Text
MANMIN 1 MAX 264ID: 933

Free-form message text

MSG02
Printer Carriage Control Code
CIDMIN 2 MAX 2ID: 934

A field to be used for the control of the line feed of the receiving printer

DSAdvance two lines before print
NPAdvance to next page before print
SSAdvance to new line before print
SE

Transaction Set Trailer

MMax: 1Area: 3Seq: 0100

To indicate the end of the transaction set and provide the count of the transmitted segments (including the beginning (ST) and ending (SE) segments)

SE01
Number of Included Segments
MN0MIN 1 MAX 10ID: 96

Total number of segments included in a transaction set including ST and SE segments

SE02
Transaction Set Control Number
MANMIN 4 MAX 9ID: 329

Identifying control number that must be unique within the transaction set functional group assigned by the originator for a transaction set